Summary Panel

CriterionSummary Outputs
Mohr-CoulombInput cohesion, friction angle, tensile strength; selected Sigma3 or SigmaN maximum.
Generalized Hoek-BrownInput classification values, modulus method, mb, s, a, tensile strength, UCS, global strength, deformation modulus, application, σ₃ₘₐₓ, and optional equivalent MC fit.
Power CurveInput a, b, c, d; selected Sigma3 or SigmaN maximum; corresponding shear strength when available; optional equivalent MC fit and shear RMSE.
Barton-BandisInput phiR, JRC, JCS; selected Sigma3 or SigmaN maximum; corresponding shear strength when available; optional equivalent MC fit and shear RMSE.

When enabled and valid, the instantaneous Mohr-Coulomb section reports the selected normal stress, tangent cohesion, and tangent friction angle.

Status Bar

  • Criterion: current failure criterion label.
  • Samples: active sample count for plotted curves.
  • Fit σ₃ₘₐₓ or Fit normal max: active computed range maximum.
  • Right-side message: calibration status or curve count ready message.

Calibration Messages

Calibration messages report missing data, missing target parameters, deleted or added rows, and successful calibration with the actual solver, iterations, fitted parameter names, raw RMSE, termination status, and bound warnings. Failures distinguish iteration-limit, evaluation-limit, and invalid-objective termination and do not apply fitted parameters.