Outputs and Interpretation
Interpret factor of safety, geometry, force balance, runout, and diagnostic outputs.
Summary Outputs
| Output | Meaning |
|---|---|
| State | Whether a valid wedge has formed. |
| Mode / Sliding Mode | Stable, Joint 1, Joint 2, Both joints, or Lifting. |
| FS / Reported FS | Primary reported factor of safety from the implemented force-balance comparison. |
| Volume | Computed wedge volume. |
| Runout R | Reported runout distance, using the governing lesser conical or pyramidal value when valid. |
| Backbreak | Horizontal setback/backbreak distance derived from the current geometry. |
Factor of Safety Outputs
| Output | Meaning |
|---|---|
| Unsupported FS | Factor of safety without passive support contribution. |
| Supported FS | Factor of safety including passive support and its effect on joint normal force. |
| Falling FS | Falling-mode factor from passive support resolved against the active-force direction. |
| Support Pressure For FS 1 | Additional uniform pressure in kPa over the exposed excavation/support face required to raise wedges with FS below 1 to FS = 1. Reports 0 when the current FS is already at least 1. |
| Friction Reserve | Controlling joint friction angle minus sliding/intersection plunge. Positive reserve indicates more available friction than required by plunge. |
Geometry and Force Outputs
| Output | Meaning |
|---|---|
| Weight | Unit weight multiplied by computed volume, reported in kN. |
| Joint 1 Area / Joint 2 Area | Computed active joint face areas. |
| Upper Area / Slope Area | Computed upper and slope face areas. |
| Normal Force 1 / Normal Force 2 | Normal force components on Joint 1 and Joint 2, reported in kN. |
| Driving Force | Magnitude of the active driving component, reported in kN. |
| Resisting Force | Magnitude of the resisting component, reported in kN. |
| Active Force | Magnitude of the combined active vector, reported in kN. |
| Passive Force | Magnitude of the resultant passive-support vector, reported in kN. |
| Rock Bolt Force | Magnitude of the effective resultant bolt vector after capacity and orientation efficiency, in kN. |
| Engaged Bolt Rows | Number of physical axial rows that geometrically cross the wedge. |
| Active Pressure / Passive Pressure | Magnitudes of active and passive face pressure contributions, reported in kN. |
| External Force | Magnitude of included external force, reported in kN. |
| Water Force | Magnitude of included joint water force, reported in kN. |
| Seismic Force | Magnitude of included seismic force, reported in kN. |
Runout Outputs
| Output | Meaning |
|---|---|
| Reported R | Selected runout distance reported by the app. |
| Conical R | Conical spill-berm runout estimate. |
| Pyramid R | Pyramidal spill-berm runout estimate. |
| Controlling Mode | Conical, Pyramid, or Pending. |
| Wedge Length L | Length term used in runout calculations when available. |
Diagnostic Outputs
| Output | Meaning |
|---|---|
| Daylighting | Whether the wedge intersection line satisfies the daylighting check. |
| Kinematic State | Plain-language description of the current wedge state. |
| Included Effects | Lists load effects included in the current force balance. |
| Plane Normals | Normal vector components for active planes. |
| Analysis Notes | Implementation-generated notes explaining special conditions, assumptions, and enabled effects. |